new idea ENGINEERING         Home  | Products  | Services  | Newsletter  | Resources  | About Us | Contact Info | Privacy Policy        

  Specializing in Enterprise Search since 1996 - including FAST, Autonomy, Google, Endeca, Dieselpoint and Lucene

Locator: NIE Home / Publications / Enterprise Search Newsletter / Volume 3 Number 3 / Article 2

Not a subscriber? Sign up at http://www.ideaeng.com/subscribe.html

Checking K2 Collection Health using WSH

By Miles Kehoe. - Volume 3 Number 3 - Spring 2006

We're always looking for ways to make life easier for our customers who are often responsible for managing and maintaining large Verity installations with command line utilities and with web management interfaces that, while easier to use, don't always provide the data that IT staffs require.

In the past we have published Windows Shell Host (WSH) scripts to perform simple K2 search and to list K2 collections, but the Operations Staff at CaseShare Systems has built an entire set of K2 management scripts based on Windows Shell Host. They've allowed us to write about one of their scripts that reports on K2 collection health, and we expect to write more about more of their script tools in the coming months.

CaseShare has done more with K2 than many of our customers, and are successfully indexing and searching tens of millions of documents as a key component of their business. As a long time Verity customer, they decided to develop these administrative scripts, first used with K2 Version 4.5, for a few main reasons:

An Introduction to the Code

We took a script CaseShare calls verity-health and customized it to work in any arbitrary K2 installation. To do this, we effectively modified some of the subroutines and functions that were written to fit into the overall CaseShare system. They have some of the best developers we've worked with, so be assured that anything that looks odd is probably from our attempts to sanitize the system.

The report that the script generates is listed in Figure 1. You can see that the report contains provides useful information that is not easily available in one place using the standard Verity utilities.

Working ctl_ender.txt
+ Setting local drive d:\colls
+ Reading in control file d:\colls\tools\ctl_ender.txt
+ Parsing configuration from d:\colls\tools\ctl_ender.txt
+ Working in d:\colls\niedocs
  0.23 GB
  Server ender
  2 ddd files
  0 mrg files
  2 did files
  4 total files
  calling mkvdk
+ Reading MKVDK Results
  Last Squeeze Date: 0000000000
  Number of Documents: 4735

Figure 1: Sample Report
The report above combines information extracted directly from the collection directory, and from the standard mkvdk utility using the little known -about flag. Figure 2 shows the invocation and output which are programmatically performed in the CaseShare script:

mkvdk.exe -collection niedocs -about -noindex -nooptimize 

mkvdk.exe - Verity, Inc. Version 5.5.0 (_nti40, Jan 21 2005)
Collection about resources:
  Creation Date: 15-Aug-2005 08:59:47 pm
  Modification Date: 11-May-2006 12:48:14 am
  Last Purge Date: 0000000000
  Last Squeeze Date: 0000000000
  Number of Documents: 4735
  Collection Creator: NEW IDEA ENGINEERING
  Collection Name: niedocs
  Collection Type:  
  Collection Description:  
  Locale Name: englishx
  Charset: 1252
  Country: US
  Language: en
  Dialect: US
  Supplier: 
  Major Version: 1
  Minor Version: 0
  Copyright Notice: InXight linguistX wrapper © 1997 Verity, Inc. All rights reserved.  
mkvdk.exe done



Figure 2: MKVDK 'About' Output
This script, like all of the tools CaseShare uses, use control files to define key collection and server parameters. The production use several additional fields, but for the purpose of this example, we are using simplified files as shown in Figure 3.
ender;niedocs
ender;doc_master

Figure 3: Sample Control File ctl_ender.txt
The general format here is servername;collection. A single control file can contain one ore more collections; the verity-health script as written supports a maximum of three control files, since CaseShare uses only three primary servers in this application. By convention, the script looks for and processes any file in the primary working directory that starts with ctl_.

The Real Work

Enough of the preliminaries: the actual code is provided in Figure 4.
''******************************************************************************
' Name:
' verity-health.vbs
'
' Requires:
' mkvdk, mapped drives for collection hosts
'
' Inputs:
' Control File location
'
' Usage:
' cscript verity-health.vbs d:\dev\scripts
'
' Purpose:
' Reads control files, finds Verity collections, 
' gather stats and sends output to screen
'
' Layout:
' Assignment, Sets, Main, Subs, Functions
'
' Based on code copyright (c)CaseShare Systems
'
'******************************************************************************

' *******************************************************
' Mapped Drive Assignment
'     Alias = Mounted_Drive:Collection_Directory
' *******************************************************
' Change these server to drive mappings here and verify the server
' names match those in sub WhichMapDrive below
Const bean = "t:\colls"
Const ender = "d:\colls"
Const ForReading=1


Dim oArgs
Dim fso, wso
Dim sMKVDK, sVerityLock, sControlFilePath
Dim dtmDateNow, dtmTimeNow, dtmYYYY, dtmMM, dtmDD, dtmHH, dtmMN, dtmSS
Dim wsoReturn, wsoCommand, sControlFile, dictControlFiles
Dim sLogFolder, sLogFolderPath, sMkvdkLogFolderPath

Set oArgs = Wscript.Arguments
Set fso = CreateObject("Scripting.FileSystemObject")
Set wso = WScript.CreateObject("WScript.Shell")
' 
' Verify these two paths are correct
sMKVDKAbout = "d:\colls\tools\mkvdk-about.cmd"
sLogFolderPath = "d:\colls\tools\logfiles\"

' *******************************************************
' Main
' *******************************************************
' administrative work begins here
Call subBanner()
Call subParseArgs()
Call subCheckControlFolder(oArgs(0))
Call subCheckMKVDKAbout()
Call subCheckTempLogFolderDir(sLogFolderPath)
Call subBuildNames()

Call subBuildFolder(sMkvdkLogFolderPath)
Call subFlightCheck()

' real work begins below
Call subBuildControlDictionary(oArgs(0))
Call subCheckCollections(sCapture)
Call subFinish()

' *******************************************************
' Sub routines
' *******************************************************
Sub subCheckCollections(sTempLogFile)
'
' locate the collecitons and examine the parts directories
' and output from mkvdk -about
'
	Dim strCurrControlFile, strDrive, i,strText
	Dim oFolder, oFile, strControlRead, objTextFile
	Dim objFSO, arrControlLines, arrCollectionLine
	Dim strControlLine, strCollectionFolder

	strCurrControlFile = dictControlFiles.items
	For i = 0 To dictControlFiles.Count -1
		Wscript.echo " "
		wscript.echo "Working " & strCurrControlFile(i)
		strDrive = WhichMapDrive(strCurrControlFile(i))
		if len(strDrive) > 1 then
			wscript.echo "+ Setting local drive " & strDrive

			Set objFSO = CreateObject("Scripting.FileSystemObject")
			strControlRead = oArgs(0) & "\" & strCurrControlFile(i)

			wscript.echo "+ Reading in control file " & strControlRead
			Set objTextFile = objFSO.OpenTextFile(strControlRead, ForReading)
			strText = objTextFile.ReadAll
			objTextFile.Close

			' looking for extra white space
			' another proud VB moment
			' see this sweet hack used for inspiration
			' http://www.microsoft.com/technet/scriptcenter/resources/qanda/may05/hey0520.mspx
			intLength = Len(strText)
			strEnd = Right(strText, 2)
			If strEnd = vbCrLf Then
		    		strText = Left(strText, intLength - 2)
			End If

			wscript.echo "+ Parsing configuration from " & strControlRead						
			arrControlLines = Split(strText, vbCrLf)
		
			For Each strControlLine in arrControlLines
			arrCollectionLine = split(strControlLine, ";")
			strServerName = arrCollectionLine(0)
			strCollectionFolder = arrCollectionLine(1)
			strCollectionPath =  strDrive & "\" & trim(strCollectionFolder)
			strCollectionPartsPath = strDrive & "\" & trim (strCollectionFolder) & "\parts"			

				iDDD = 0
				iMrg = 0
				iDID = 0
				if DoesFolderExist(strCollectionPath) = 0 then
					wscript.echo "+ Working in " & strCollectionPath
					wscript.echo "  " & GetCollectionSize(strCollectionPartsPath) &  " GB"
					wscript.echo"  Server " & strServerName
					Set oFolder = fso.GetFolder(strCollectionPartsPath)
					iTotalFiles = 0
					for each oFile in oFolder.files
						if lcase(right(oFile, 3)) = "did" then
							iDID = iDID + 1
						end if
						if lcase(right(oFile, 3)) = "ddd" then
							iDDD = iDDD + 1
						end if
						if lcase(right(oFile, 3)) = "mrg" then
							iMrg = iMrg + 1
						end if
						iTotalFiles = iTotalFiles + 1
					next
					wscript.echo "  " & iDDD & " ddd files"
					wscript.echo "  " & iMrg & " mrg files"	
					wscript.echo "  " & iDID & " did files"					
					wscript.echo "  " & iTotalFiles & " total files"

					sTempLogFile = sMkvdkLogFolderPath & "\" & arrCollectionLine(1) & ".log"
					wsoCommand = sMKVDKAbout & " " & strCollectionPath & " " &  sTempLogFile
					wscript.echo "  " & "calling mkvdk"
					wsoReturn = wso.Run(wsoCommand,7,true)
					Set objTextFile = objFSO.OpenTextFile(sTempLogFile, ForReading)
					strText = objTextFile.ReadAll
					objTextFile.Close
					wscript.echo "+ Reading MKVDK Results "
					arrMKVDKLines = Split(strText, vbCrLf)
					For Each strMKVDKResult in arrMKVDKLines
						If InStr(strMKVDKResult, "Last Squeeze Date") Then
							wscript.echo "  " & trim(strMKVDKREsult)
						End If
						If InStr(strMKVDKResult, "Number of Documents") Then
							wscript.echo "  " & trim(strMKVDKREsult)
						End If
					Next				
				end if
			Next
		End if

	Next
End Sub

'
' Create a wsh directory structure that contains the names of all
' control files found in the directory given at run time
'
Sub subBuildControlDictionary(strControlFilePath)
	Dim oFolder, oFile
	Set oFolder = fso.GetFolder(strControlFilePath)
	Set dictControlFiles = CreateObject("Scripting.Dictionary")
	
	wscript.echo ""
	wscript.echo "Finding control files"
	i=0
	For Each oFile in oFolder.Files
		if left(oFile.Name, 4) = "ctl_" then
			Wscript.Echo "+ Found " & oFile.Name
			dictControlFiles.add i, oFile.Name
			i = i + 1
		end if
	Next
	if i < 1 then
		Wscript.Echo "Error:"
		Wscript.Echo "====================================="
		Wscript.Echo "Could not find control files in " & oArgs(0)
		wscript.Echo ""
		Wscript.Quit 1
	End if
	if dictcontrolFiles.Count > 4 then
		wscript.Echo ""
		wscript.echo "Configuration Alert"
		Wscript.Echo "====================================="
		Wscript.Echo "Found more than four control files."
		wscript.Echo "This script will continue, but may need to be modified."
		wscript.Echo ""
	end if
End Sub

Sub subParseArgs()
'
' read working directory from command line
'
	if oArgs.Count < 1 then
		Wscript.Echo "Error:"
		Wscript.Echo "====================================="
		Wscript.Echo ""
		wscript.Echo "Requires path to control files"
		wscript.echo "used to handle operations"
		wscript.echo "with Verity collections"
		wscript.quit 1
	End if
	wscript.echo "+ Parsed arguments"
End Sub

Sub subFinish()
	wscript.echo ""
	wscript.echo "Script completed"
	wscript.echo "Start "&  dtmDateNow & " " & dtmTimeNow
	wscript.echo "Stop " & date & " " & Time
End Sub

Sub subFlightCheck()
'
' confirm that we're ready to go by giving user 
' 10 seconds to break out of the script
'
	wscript.echo ""
	wscript.echo "You provided the following arguments"
	for i = 0 to oArgs.Count -1
		wscript.echo "     " & oArgs(i)
	Next
	wscript.echo ""
	wscript.echo "Script will read control files found in "
	wscript.echo oArgs(0)
	wscript.echo "and try to determine their health"
	wscript.echo "====================================="
	wscript.echo "Hit Ctrl+C now to cancel."
	wscript.echo "Script resumes in 5 seconds"
	wscript.echo ""
 	wscript.sleep(5000)
End Sub

Sub subBanner()
	Wscript.echo ""
	Wscript.echo "orb-verity-health.vbs"
	wscript.echo "==================="
	wscript.echo "(c) based on code copyright (c) caseshare 2005"
	Wscript.echo ""
End Sub

Sub subCheckTempLogFolderDir(sFolderPath)
'
' Verify that the 'parent' log directory exists i
' or create it if it does not 
'
If DoesFolderExist(sControlFilePath) = -1 Then
        Wscript.Echo "Warning:"
        Wscript.Echo "====================================="
        Wscript.Echo sFolderPath
        wscript.Echo "Folder does not exist; creating"

	If CreateTempLogFolder(sFolderPath) = -1 Then
	        Wscript.Echo "Error:"
	        Wscript.Echo "====================================="
	        Wscript.Echo sFolderPath & " could not be created"
	        wscript.Echo ""
	        Wscript.Quit 1
	Else
	        wscript.echo "+ Temp log folder created " & sFolderPath
	End If
	
Else
        wscript.echo "+ Control folder exists"
End if

End Sub


Sub subCheckControlFolder(sControlFilePath)
wscript.echo "in CheckControlFolder parm is " & sFolderPath
If DoesFolderExist(sControlFilePath) = -1 Then
	Wscript.Echo "Error:"
	Wscript.Echo "====================================="
	Wscript.Echo oArgs(0)
	wscript.Echo "Folder does not exist"
	wscript.quit 1
Else
	wscript.echo "+ Control folder exists"
End if
End Sub


Sub subCheckMKVDKAbout()
If DoesFileExist(sMKVDKAbout) = -1 Then
	Wscript.Echo "Error:"
	Wscript.Echo "====================================="
	Wscript.Echo sMKVDKAbout & " does not exist."
	wscript.Echo ""
	Wscript.Quit 1
Else
	wscript.echo "+ mkvdkAbout found"
End If
End Sub

Sub subCheckMKVDK()
If DoesFileExist(sMKVDK) = -1 Then
	Wscript.Echo "Error:"
	Wscript.Echo "====================================="
	Wscript.Echo sMKVDK & " does not exist."
	wscript.Echo ""
	Wscript.Quit 1
Else
	wscript.echo "+ mkvdk found"
End If
End Sub

Sub subBuildFolder(sFolderPath)
If CreateTempLogFolder(sFolderPath) = -1 Then
	Wscript.Echo "Error:"
	Wscript.Echo "====================================="
	Wscript.Echo sFolderPath & " could not be created"
	wscript.Echo ""
	Wscript.Quit 1
Else
	wscript.echo "+ Temp log folder created " & sFolderPath
End If
	
End Sub

Sub subBuildNames()
	dtmDateNow = date
	dtmTimeNow = time

	dtmYYYY = DatePart("yyyy", dtmDateNow)
	dtmMM = DatePart("m", dtmDateNow)
	dtmDD = DatePart("d", dtmDateNow)
	dtmHH = DatePart("h", dtmTimeNow)
	dtmMN = DatePart("n", dtmTimeNow)
	dtmSS = DatePart("s", dtmTimeNow)

	If dtmMM < 10 Then
		dtmMM = "0" & dtmMM
	End if
	If dtmHH < 10 Then
		dtmHH = "0" & dtmHH
	End if
	If dtmMN < 10 then
		dtmMN = "0" & dtmMN
	End if
	If dtmDD < 10 Then
		dtmDD = "0" & dtmDD
	End if
	If dtmSS < 10 Then
		dtmSS = "0" & dtmSS
	End If
	sLogFolder = "_orb-" & dtmYYYY & dtmMM & dtmDD & dtmHH & dtmMN & dtmSS
	sMkvdkLogFolderPath = sLogFolderPath & sLogFolder

End Sub


' *******************************************************
' functions
' *******************************************************
function WhichMapDrive(strFileName)
	if lcase(strFileName) = "ctl_ender.txt"  then
		whichMapDrive = ender
	End If
	if lcase(strFileName) = "ctl_bean.txt" then
		whichMapDrive = bean
	End If	
end function

function DoesFileExist(FilePath)
Dim fso
	Set fso = CreateObject("Scripting.FileSystemObject")
	if not fso.FileExists(FilePath) then
		DoesFileExist = -1
	else
		DoesFileExist = 0
	end if
	Set fso = Nothing

end function

function CreateTempLogFolder(sFolderPath)
Dim fso
	set fso = CreateObject("Scripting.FileSystemObject")
	if DoesFolderExist(sFolderPath) < 0 then
		fso.CreateFolder(sFolderPath)
		if DoesFolderExist(sFolderPath) < 0 then
			CreateTempLogFolder = -1
		else
			createTempLogFolder = 0
		end if
	else
		CreateTempLogFolder = 0
	end if
	set fso = nothing

end function

function DoesFolderExist(FolderPath)
Dim fso

	Set fso = CreateObject("Scripting.FileSystemObject")
	If not fso.FolderExists(FolderPath) Then
		DoesFolderExist = -1
   	else
     		DoesFolderExist = 0
	end if
	Set fso = Nothing

End Function

function GetCollectionSize(CollPath)
Dim s, oFolder, oFolderItem, fso, wso

	s = -1
	Set fso = CreateObject("Scripting.FileSystemObject")
	Set wso = CreateObject("Shell.Application")
	Set oFolder = wso.Namespace(CollPath)
	Set oFolderItem = oFolder.Self
	strPath = oFolderItem.Path
	Set oFolder = fso.GetFolder(strPath)
	s = round ((oFolder.size / 1024 / 1024 / 1024 ), 2)
	set oFolder = Nothing
	set fso = Nothing

GetCollectionSize = s
end function

Figure 4: WSH Script
The script uses an external file, mkvdk-about.cmd, to actually run mkvdk. You could probably call the program directly from within verity-health, but it was easier to pass parameters and let the operating system invoke the program. mkvdk-about.cmd is listed in Figure 5.
d:\verity\k2\_nti40\bin\mkvdk.exe -collection %1 -about -noindex -nooptimize > %2

Figure 5: mkvdk-about.cmd Script
The script, called from verity-health, accepts the collection name and returns the logfile out.

Making it Work

To use the above tool, create a directory for the scripts and control files. Then: On our test system, we are using D:\colls\tools to store the following files:
	ctl_bean.txt
	ctl_ender.txt
	mkvdk-about.cmd
	verity-health.vbs
It will also be where the logfiles directory will be created.

To run the script, enter the following command:

	cscript verity-health.vbs d:\colls\tools   /nologo
You should see an output like that in Figure 1 above. You can append the /NOLOGO command to suppress the Microsoft header information.

Note: You may see a 'Malicious Script Alert' depending on the security settings for your system. To be safe, confirm that the operation the script is performing is one you are comfortable with; and allow the activity once, for the entire script, or disallow it and confirm the operation is benign.

The logfile directory has a more complete dump of data than the script as shown actually uses. Browsing those logfiles may give you additional ideas for content to include in your report.

Summary

Windows Shell Script is a tool many It professionals use for administrative scripting in their corporate environments. The scripts listed here, thank to CaseShare, may provide some information you want to review regularly in your environment.

As always, if you have any questions about the script, or any other search technical tasks, feel free to mail us any time!


Home  | Products  | Services  | Newsletter  | Resources  | About Us  | Contact Info  | Privacy Policy